Non-Traditional Threats In Data Center Facilities Vulnerability Asssessment...
1. Place external air intakes as high above ground level as possible. This is perhaps the most important of all mitigation with respect to chemical, biological, or radiological threats.2. Filter...
View ArticleClosed Circuit Television (CCTV) Performance Criteria And Technical...
PERFORMANCE CRITERIA (a) Facial Identification: identify individual(s) from the displayed/ recorded image or (b) Situational Awareness: discern actions/events within a defined area of coverage from the...
View ArticleISO 27001 Physical Access Authorization System Performance Criteria Checklists
HIGH-LEVEL SYSTEM ARCHITECTURE (a) Globally distributed (b) Centrally and regionally monitored (c) Common software application managementPHYSICAL ACCESS AUTHORIZATION (a) Company ID card authorization...
View ArticleData Center Exterior Barrier Performance Criteria And Technical...
1. Barriers should circumscribe the base of the facility if protecting the entire facility.2. Barrier emplacement should be at the maximum allowable distance from the facility or the minimum required...
View ArticleData Center Window Anti-Blast Methods Technical Specifications
I. Polyester Anti-Shatter Film Applied to Glass Panes A. 175 m thickness for standard window panes.B. 300 m thickness for panes over 6 square meters, over 8 mm thick, or ground floor windows.C. 100 m...
View ArticleDisaster Response and DRP Checklists
Disaster Response and DRP Checklists- Provide information to emergency responders - Assess the damage to the organization - Determine the status of employees - Determine the status of the building -...
View ArticleTop 5 Protecting against Physical ATM Thefts
Top 5 Protecting against Physical ATM TheftsPhysical Placement A carefully placed ATM machine can dissuade attackers from choosing it as a target. If possible, place or relocate ATM machines into the...
View ArticleData Center Security Guidelines for Facility and Site Selections
Data Center Security Guidelines for Facility and Site Selections Site-related security guidelines1. Avoid the following: - Iconic, trophy, historic, listed, or high-profile sites and/or locations near...
View ArticleComparison of Data Center Standard - ANSI/TIA/EIA-942 vs Uptime Institute
Download free comparison between ANSI/TIA/EIA-942 vs Uptime Institute ANSI/TIA/EIA-942, Telecommunication Infrastructure Standard for Data Centers criteria: - Number of Delivery Parts - Redundant...
View ArticleData Center Tier 4 Requirements Templates
Data Center Tier 4 Requirements Based on Uptime Institute and ANSI/TIA/EIA-942Uptime Institute, Data Center Site Infrastructure Tier Standard: Topology Active Capacity Components to Support the IT...
View Article